ROTARY FUEL INJECTION PUMP WEAR TESTING USING A 30 %/ 70% ATJ/F-24 FUEL BLEND
Abstract:
A 3070 blend of ATJF-24 fuels at maximum CILI additive concentration were operated in rotary, mechanical, fuel-lubricated, fuel injection pumps for a 1000-hour target at 77 C and 40 C fuel inlet temperatures. Both tests with the 24-ppm CILI treatment lasted the 1000-hour duration, but with moderate wear and degraded fuel injection pump performance.