Multi-Shot Performance of a 1-MV, 15-kA Rod-Pinch-Like Diode for Radiography

reportActive / Technical Report | Accession Number: ADA638640 | Open PDF

Abstract:

A rod-pinch diode, modified to operate in a non-pinching mode, is tested for multi-shot operation at 1 MV and 15 kA. Three different geometry diodes are used. A 3.2-mm or 4.7-mm diameter tungsten-rod anode, tapered on the end, is used to minimize anode damage and to maintain a small source size. The diode parameters are chosen to avoid beam pinching. The diode operates successfully for at least 5 to 9 shots depending on the geometry. The first shot operates at higher impedance due to late-time anode ion turn-on. Multi-shot operation is limited by anode rod damage. The dose on-axis at 1 meter from the source is 0.7 to 0.9 radSi and varies by plus or minus 20 from shot to shot. The source diameter is 2 to 4 mm and decreases from the first to the last shot even though the dose is not degraded.

Security Markings

DOCUMENT & CONTEXTUAL SUMMARY

Distribution:
Approved For Public Release
Distribution Statement:
Approved For Public Release; Distribution Is Unlimited.