Vacuum Insulator Failure Measurements and Improvement

reportActive / Technical Report | Accession Number: ADA636486 | Open PDF

Abstract:

Cones, cylinders, and insulators have been tested with a 3 nanosecond full width halfmax pulse. These insulators were made of epoxy, acrylic, lexan, and nylon. The tests were conducted with cone insulators at 45 degrees, -45 degrees, and 0 degree. Additionally, tests were conducted with a plug in the anode that reduces the anode stress, and anodized cathodes. Best results were obtained with both an anodized cathode and an anode plug where failure was through the solid dielectric at 600 kVcm. Results of this testing will be presented.

Security Markings

DOCUMENT & CONTEXTUAL SUMMARY

Distribution:
Approved For Public Release
Distribution Statement:
Approved For Public Release; Distribution Is Unlimited.

RECORD

Collection: TR
Identifying Numbers
Subject Terms