Experimental Studies of Ageing in Electrolytic Capacitors

reportActive / Technical Report | Accession Number: ADA562492 | Open PDF

Abstract:

Understanding the ageing mechanisms of electronic components critical avionics systems such as the GPS and INAV are of critical importance. Electrolytic capacitors and MOSFETs have higher failure rates among the components of DC-DC power converter systems. Our current work focuses on analyzing and modeling electrolytic capacitor degradation and its effects on the output of DC-DC converter systems. The output degradation is typically measured by an increase in ESR Equivalent Series Resistance and decrease in the capacitance value over long periods of use even under nominal operating conditions. Typically the primary effect of degradation is increased ripple current and this has adverse effects on downstream components. For example, in avionics systems where the power supply drives a GPS unit, ripple currents can cause glitches in the GPS position and velocity output, and this may cause errors in the Inertial Navigation INAV system, causing the aircraft to fly off course. In this paper, we present the details of our ageing methodology along with details of experiments and analysis of the results.

Security Markings

DOCUMENT & CONTEXTUAL SUMMARY

Distribution:
Approved For Public Release
Distribution Statement:
Approved For Public Release; Distribution Is Unlimited.

RECORD

Collection: TR
Identifying Numbers
Subject Terms