Gamma-Insensitive Fast Neutron Detector with Spectral Source Identification Potential

reportActive / Technical Report | Accession Number: ADA540497 | Open PDF

Abstract:

Calculations are presented to support the claim that fast neutron detection systems can achieve higher performance in detecting weak neutron sources than conventional thermal neutron detection systems involving moderators. Minimum Detectable Limits MDL are used as a comparative metric, more representative than the metric of absolute sensitivity, which does not take into account the influence of natural backgrounds. Monte Carlo simulations are used to show that heavily shielded neutron sources emit a substantial fraction of fast neutrons. Arguments are presented to support the claim that fast neutron detection systems are superior at defeating heavy neutron shielding than thermal systems.