Measuring Fluorescent Dye in the Bubbly and Sediment-Laden Surfzone

reportActive / Technical Report | Accession Number: ADA514515 | Open PDF

Abstract:

Decisions about recreational beach closures would be enhanced if better estimates of surfzone contaminant transport and dilution were available. In situ methods for measuring fluorescent Rhodamine WT dye tracer in the surfzone are presented, increasing the temporal and spatial resolution over previous surfzone techniques. Bubbles and sand suspended by breaking waves in the surfzone interfere with in situ optical fluorometer dye measurements, increasing the lower bound for dye detection 1 ppb and reducing quenching measured dye concentrations. Simultaneous turbidity measurements are used to estimate the level of bubble and sand interference and correct dye estimates. After correction, root-mean-square dye concentration errors are estimated to be 5 of dye concentration magnitude, thus demonstrating the viability of in situ surfzone fluorescent dye measurements. The surfzone techniques developed here may be applicable to other environments with high bubble and sand concentrations e.g., cascading rivers and streams.

Security Markings

DOCUMENT & CONTEXTUAL SUMMARY

Distribution:
Approved For Public Release
Distribution Statement:
Approved For Public Release; Distribution Is Unlimited.

RECORD

Collection: TR
Identifying Numbers
Subject Terms