Vraagstukken besmettingsbeheersing prio 3 (Questions Regarding Contamination Control, Priority 3)

reportActive / Technical Report | Accession Number: ADA493850 | Open PDF

Abstract:

The GDS2000 delivery device is used for application of both simulant decontamination solution as well as for GDS2000. After use of this equipment, residual amounts of product can remain on or in the equipment. Furthermore the materials decontaminated with GD5 need to be cleaned as well. For both decontamination applications it needed to be investigated how the equipment or the decontaminated surface can be adequately cleaned afterwards. For the GDS2000 equipment adequate cleaning can be obtained by rinsing the vessel three times with a fresh aliquot water 14 of the vessel, with each time calmly moving the vessel from top to bottom during 10 seconds. For surfaces decontaminated with GD5 three times of 10 seconds rinsing with water proved to be adequate for smooth, inert surfaces. For adsorbing surfaces like linoleum or NBC clothing the GD5 proved to be removed much less efficient. Check with a pH paper which changes color by the caustic GD5 will prove residual GD5 in an easy way.

Security Markings

DOCUMENT & CONTEXTUAL SUMMARY

Distribution:
Approved For Public Release
Distribution Statement:
Approved For Public Release; Distribution Is Unlimited.

RECORD

Collection: TR
Identifying Numbers
Subject Terms