Design and Preliminary Characterization of the USNO Rubidium Fountain
Abstract:
We have built and begun characterization of an engineering prototype rubidium atomic fountain at the USNO for use in its clock ensemble. We achieve short-term stability of 1.4 10exp -13tauexp 12, which meets the desired performance for characterizing maser drift. We will discuss the design, operation, and preliminary characterization of this device.