Reduced Air Emissions for Hard Chrome Plating at the NADEP NAS North Island, San Diego Using an Alternative Emission Control Technology

reportActive / Technical Report | Accession Number: ADA460123 | Open PDF

Abstract:

The Naval Air Systems Command Depot NADEP facility located on the Naval Air Station NAS North Island, San Diego, CA currently has five 5 hard chrome plating tanks in operation. The facility typically plates 3-5 million amp-hours per year and is identified as a Small Hard Chromium Electroplating Facility by the San Diego Air Pollution Control District. This presentation addresses the implementation of encapsulating tank covers, hereafter referred to as the Chrome Plating Emission Elimination Device EED, on the NADEPs hard chrome plating process tanks, as an alternate control devise used to eliminate Cr6 emissions to the outside environment, reduce operating costs, and provide enhanced operator safety and exposure in the chrome plating facility.

Security Markings

DOCUMENT & CONTEXTUAL SUMMARY

Distribution:
Approved For Public Release
Distribution Statement:
Approved For Public Release; Distribution Is Unlimited.

RECORD

Collection: TR
Identifying Numbers
Subject Terms