Total Petroleum Hydrocarbon (TPH) Criteria Working Group Field Demonstration Project: Tinker Air Force Base, Oklahoma

reportActive / Technical Report | Accession Number: ADA453492 | Open PDF

Abstract:

Site 21 at Tinker Air Force Base, Oklahoma was selected as a demonstration site for the Total Petroleum Hydrocarbon Working Group approach for establishing Risk Based Screening Levels. The site had been previously characterized using conventional analyses and was recommended for natural attenuation. Contaminants included JP-4 and diesel fuels. Groundwater and soil samples were collected and analyzed using the Direct Method, specified by the Working Group. A Tier I risk assessment was performed to determine clean-up levels. Average site concentrations did not exceed the average Risk Based Screening Levels. The bulk of the contaminated soil has not weathered significantly, but the recommendation for natural attenuation was confirmed.

Security Markings

DOCUMENT & CONTEXTUAL SUMMARY

Distribution:
Approved For Public Release
Distribution Statement:
Approved For Public Release; Distribution Is Unlimited.

RECORD

Collection: TR
Identifying Numbers
Subject Terms