Remedial Action Option Evaluation in Support of Intrinsic Remediation for the Jet Fuel Transfer Line Southwest of Building 412 and the POL Yard. Volume 1: Text

reportActive / Technical Report | Accession Number: ADA381496 | Open PDF

Abstract:

This report presents the results of a remedial action option evaluation RAE performed by Parsons Engineering Science, Inc. Parsons ES at Truax Field Air National Guard Base, Wisconsin to evaluate the use of intrinsic remediation natural attenuation with long-term monitoring LTM as a remedial option for dissolved benzene, toluene, ethylbenzene, and xylene BTEX contamination in the shallow saturated zone in the vicinity of the former jet fuel transfer line southwest of Building 412 and the petroleum, oils, and lubricants POL yard the site. Soil and ground water contamination is documented for the site, with contamination being present in the aqueous i.e., dissolved and gaseous phases and as residual light nonaqueous-phase liquid LNAPL within the aquifer matrix. There is no evidence of mobile LNAPL free product at this site. This study focused on the impact of dissolved BTEX on the shallow ground water system at the site. Site history and the results of soil and ground water investigations conducted previously are also summarized in this report.

Security Markings

DOCUMENT & CONTEXTUAL SUMMARY

Distribution:
Approved For Public Release

RECORD

Collection: TR
Identifying Numbers
Subject Terms