Man in Simulant Testing (MIST) of Domestic Preparedness Suits Kappler Model 42483 Responder CSM Level a Suit.

reportActive / Technical Report | Accession Number: ADA365341 | Open PDF

Abstract:

Testing of the Responder CSMregistered Level A suit ensemble was conducted according to MIST test guidelines promulgated by the Joint Services Lightweight Integrated Suit Technology JSLIST test working group. This testing was conducted with the chemical agent simulant methyl salicylate MS to determine the protective capability of the suit against chemical warfare agents CWA. This testing was to fill in data gaps on commercial protective suits they are not certified by either NIOSH or OSHA for CWA so they can be used by emergency personnel at sites that have been infiltrated by terrorist assailants with unknown chemical andor biological weapons of mass destruction. The testing showed that the Responder CSMregistered suit, when worn in the Level A mode with self-contained breathing apparatus SOBA, provided wearers with an overall protection factor of 1686.

Security Markings

DOCUMENT & CONTEXTUAL SUMMARY

Distribution:
Approved For Public Release

RECORD

Collection: TR
Identifying Numbers
Subject Terms