Performance Evaluation of a 22.5/30 KW 270 Volts Direct Current Generator System

reportActive / Technical Report | Accession Number: ADA275106 | Open PDF

Abstract:

This report documents the electrical system performance testing of a 12-pole, wound rotor machine with integral 31 speed increaser and rectifier, 22.530 kW 270 Vdc generator system. The performance testing was accomplished in the generator test facility of the Aerospace Power Division WLPOOC-1. This report also documents WLPOOC-ls Data Acquisition System modified for 270 Vdc test and analysis. Generator system parameters measured include transient responses to load applications and removals, ripple voltages, distortion spectrums, and fault currents. Results were compared to electrical system characteristics specified in MIL-STD-704E.

Security Markings

DOCUMENT & CONTEXTUAL SUMMARY

Distribution:
Approved For Public Release
Distribution Statement:
Approved For Public Release; Distribution Is Unlimited.

RECORD

Collection: TR
Identifying Numbers
Subject Terms