Feasibility of a Super High Energy Density Battery of the Li/BrF3 Electrochemical System
Abstract:
To date, design and construction of a material handling and measurement system along with the apparatus required for waste material disposal has been completed. Preliminary corrosion screening of potential case materials is currently underway. A review of the literature, has led us to the use of Monel trademark 400 as the material of construction for the handling and measurement system. The inherent stability of this material with bromine trifluoride in its liquid state is crucial to ensure that contamination does not occur during storage and handling. For applications which require a flexible or transparent material, items fabricated from perfluoroalkyoxy polymers Teflon trademark PFA were utilized. One such application encountered was in the design of the graduated tank which allows visual inspection of the material prior to dispensing. Containers used for compatibilitycorrosion testing were also constructed of PFA.