National Program for Inspection of Non-Federal Dams. Country Club (MA 00756), Connecticut River Basin, Northampton, Massachusetts. Phase I Inspection Report.
Abstract:
The dam is basically comprised of 2 stone masonry vertical faced spillways. The main spillway has a length of 69 ft. and a structural height of 32 ft. The secondary spillway has a length of 30 ft. and a height of about 9 ft. The visual inspection did not disclose any findings that indicate an immediate unsafe condition. The size classification is small with a hazard potential of significant. Due to the lack of drawdown capabilities, the dam is considered in fair condition. Author.
Security Markings
DOCUMENT & CONTEXTUAL SUMMARY
Distribution:
Approved For Public Release, Document Partially Illegible
Distribution Statement:
Availability: Document Partially Illegible.
RECORD
Collection: TR