An Improved Model for a Once-through Counter-Cross-Flow Waste Heat Recovery Unit

reportActive / Technical Report | Accession Number: ADA134817 | Open PDF

Abstract:

An improved model for a once-through counter-cross-flow waste heat recovery unit with a segmented fin-tube arrangement was developed. The model was coded in FORTRAN IV computer language for use on an IBM-3033 computer system, and was tested for various conditions of uniform and nonuniform gas flow distributions. Additional parameters varied were heat exchanger size, steam outlet pressure, steam outlet temperature and gas flow rate. The effect of each variation on WHRU performance was evaluated and the interrelationship discussed. Results indicate the ideal design is a high steam temperature, low operating pressure, flow distribution controlled heat exchanger.