Abstract:

The overall goal of this program was to develop a digital ultrasonic correlation system for NDE application of greater versatility and capability than the successful analog system developed in-house at AFWALMLLP. SRL had only limited success in meeting this overall goal. The program broke into two complementary tasks 1 development of an all-digital PulserReceiver with a bandwidth of 85 MHz and a maximum gain of 80 dB and 2 development of a pseudo-random correlation unit. The PulserReceiver met all of its necessary requirements however, the correlation unit suffered from a technical design decision made early in the program as to the number of bits used in the correlation process. The decision based upon both cost and the results of the computer model of an 8-bit correlation system was to utilize 1-bit correlation. This choice led to an unavoidable and most undesirable nonlinearity in the correlated signal output when the input signalnoise ratio approached unity. This unfortunate consequences has restricted the versatility and capability of the entire system.