Catoptric X-Ray Optical System (For Use in Laser-Fusion Diagnostics)
Abstract:
A compound x-ray imaging device is being developed as an aid in the diagnostics of a laser-fusion process which involves a pellet about 100 microns in diameter. While previous reports have dealt with the use of certain aspheric surfaces in the x-ray imaging process, this report is confined to a thorough investigation of the use of Abbes sine condition at grazing angles of incidence in the case of a single reflector. Author
Security Markings
DOCUMENT & CONTEXTUAL SUMMARY
Distribution:
Approved For Public Release
RECORD
Collection: TR