This report evaluates performance capabilities of a modified holographic nondestructive testing system. Specifically, the problem considered is that of reducing the obscuring background contour pattern which occurs when a vacuum stress is applied to honeycomb shelter panels undergoing holographic inspection for subsurface defects. Rather than optically masking the interference fringes, application of a compensating vacuum is investigated. The report also examines optimal photographic exposure and development times to obtain clearest test results with the holographic interferometer. Author