The Compatibility of VARIOUS Metals with MHF-3

reportActive / Technical Report | Accession Number: AD0872299 | Open PDF

Abstract:

The compatibility of various pure metals with MHF-3 was determined at 74C 165F. Metals investigated included titanium, copper, iron, aluminum, and nickel in the annealed and cold-worked conditions, and chemically deposited chromium. Tests were conducted in an all pyrex, torch-sealed pressure vessel. Pressure changes were recorded over a 94 day period. Post exposure evaluations of the metals were made by electron microscopic examination, microprobe analysis, and tensile tests.