The Compatibility of VARIOUS Metals with MHF-3
Abstract:
The compatibility of various pure metals with MHF-3 was determined at 74C 165F. Metals investigated included titanium, copper, iron, aluminum, and nickel in the annealed and cold-worked conditions, and chemically deposited chromium. Tests were conducted in an all pyrex, torch-sealed pressure vessel. Pressure changes were recorded over a 94 day period. Post exposure evaluations of the metals were made by electron microscopic examination, microprobe analysis, and tensile tests.
Security Markings
DOCUMENT & CONTEXTUAL SUMMARY
Distribution:
Approved For Public Release
Distribution Statement:
Approved For Public Release; Distribution Is Unlimited.
RECORD
Collection: TR