PROPOSED SPECIFICATION RF HIGH VOLTAGE INSULATOR LINK FOR CRANES FILAMENT WOUND PLASTIC.

reportActive / Technical Report | Accession Number: AD0822188 | Need Help?

Abstract:

The Naval Applied Science Laboratory has developed a military specification for the fabrication and electrical and mechanical evaluation of an RF high voltage insulator link for cranes. Low electrical capacitance, high tensile strength and fail-safe features are obtained by using two bands of pre-impregnated epoxy-fiberglass roving wound on two zinc-coated steel saddles. Drawings and procedures for the fabrication and testing of 15, 30 and 50 ton links are included. Author

Security Markings

DOCUMENT & CONTEXTUAL SUMMARY

Distribution:
Approved For Public Release

RECORD

Collection: TR
Identifying Numbers
Subject Terms