HY-80 SUBMERGED-ARC, FLUX (UNIONMELT 103) AND ELECTRODE (OXWELD 103); LINDE CO., NEW YORK 17, N. Y. EXHIBITOR; EXPLOSION BULGE TESTS OF.

reportActive / Technical Report | Accession Number: AD0820036 | Need Help?

Abstract:

Sample weldments exhibited strong magnetic particle indications along appreciable lengths of heat affected zone. More detailed study indicated that the effect was due to overlap of weld reinforcement and not a crack. While explosion bulge results indicate that this does not appear to be deleterious, it could introduce some difficulty in the non-destructive testing of weldments. On the basis of the tests conducted, it is recommended that the subject materials be considered satisfactory for the welding of HY-80.