SECONDARY PRESSURE REGULATOR TEST.
Abstract:
The purpose of this investigation was to evaluate a secondary pressure regulator for its suitability as a secondary or lockout regulator in the propellant pressurization system. The test requirements included determination of leakage, lockout pressure, flow capacity and response to vibration and acceleration environments. Author
Security Markings
DOCUMENT & CONTEXTUAL SUMMARY
Distribution:
Approved For Public Release
RECORD
Collection: TR