Ferro-Cement Construction Panels

reportActive / Technical Report | Accession Number: AD0781644 | Open PDF

Abstract:

Two designs of multipurpose ferro-cement construction panels were evaluated as to their versatility for military applications and their strength under flexural loads. The recommended panel design has a thickness of 12 in., width of 12 in., length of 8 ft, cross-section of a modified channel, and weight of 86 lbs. Ultimate load carrying ability of the panel under single point flexure was 1,545 lbs which corresponded to an ultimate flexural stress of 4,300 psi for the ferro-cement material. Tests on the corrosion resistance of ferro- cement were also conducted in a salt spray chamber for up to 6 months. Visual observation of the panel surfaces showed rust stains that indicated substantial corrosion of the steel reinforcement however, the average ultimate strength of the specimens was not significantly reduced.

Security Markings

DOCUMENT & CONTEXTUAL SUMMARY

Distribution:
Approved For Public Release
Distribution Statement:
Approved For Public Release; Distribution Is Unlimited.

RECORD

Collection: TR
Identifying Numbers
Subject Terms