Common Digitizer (FYQ-47) Radio Frequency Interference Measurements at the Elwood, New Jersey, Long Range Radar Site.

reportActive / Technical Report | Accession Number: AD0767965 | Need Help?

Abstract:

Operating Long Range Radar Sites LRRS have reported that the Common Digitizer CD interferes with the Back-Up Emergency Communications BUEC equipments when the CD doors are OPENED for maintenance purposes. This problem was investigated. The investigation consisted of making Radio Frequency Interference RFI field strength measurements at various locations, both inside and outside the LRRS building as well as on the roof and radome catwalk. The measurements were made for various combinations of equipments being on with the CD doors both OPENED and CLOSED. It was determined that the CD with doors OPEN is the major source of RFI. The radiating source within the CD was traced to its core memory. With the CD doors CLOSED, RFI is reduced to negligible levels furthermore, the roof of the building reduces the CD RFI to negligible proportions. Modified author abstract

Security Markings

DOCUMENT & CONTEXTUAL SUMMARY

Distribution:
Approved For Public Release

RECORD

Collection: TR
Identifying Numbers
Subject Terms