Pulsed Gain Measurements on CO2 Lasers.

reportActive / Technical Report | Accession Number: AD0751620 | Need Help?

Abstract:

An efficient procedure for determining the operational potential of a laser system is the experimental measurement of gain. Two laser systems, a flowing CO2-N2-He laser and a chemical CO2-HN3 laser, were studied using a pulsed gain measurement technique. The experimental investigation indicated that the flowing CO2-N2-He laser system could produce lasing action and that the saturation parameter was 15 wattssq. cm. The experimental results for the chemical laser show a gain of approximately 8 per meter and agree qualitatively with a computer model of the CO2-HN3 laser. Author

Security Markings

DOCUMENT & CONTEXTUAL SUMMARY

Distribution:
Approved For Public Release

RECORD

Collection: TR
Identifying Numbers
Subject Terms