Thermal Aging Studies of Encapsulated Motorette Insulation Systems
Abstract:
Thermal aging studies were conducted on four epoxy encapsulated insulation systems on motorettes to establish their thermal ratings. Encapsulation of Class A and B INSULATION SYSTEMS RESULTED IN UPGRADING THE class A system from 105 to 138 C and the Class B system from 130 to 150 C. It is recommended that the encapsulated insulation systems studied be rated thermally Class B.
Security Markings
DOCUMENT & CONTEXTUAL SUMMARY
Distribution:
Approved For Public Release
Distribution Statement:
Approved For Public Release; Distribution Is Unlimited.
RECORD
Collection: TR