DETERMINING PLASMA VOLUME, BLOOD VOLUME, AND RED CELL MASS WITH 125I.
Abstract:
A standard method was used for determining plasma volume with radioiodinated human serum albumin RISA labeled with 125I. A typical plasma volume value found with this method is 37 ml.kg., within the normal range of 27.6 to 52.0 plus or minus 6.1 ml.kg. By use of indirect measurements, the total blood volume and red cell volume can also be determined. Values for these were total blood volume, 67 ml.kg. and red cell volume, 30 ml.kg. Author