EVALUATION OF REWRAPPED SOLDERLESS WRAPPED CONNECTIONS.
Abstract:
A typical one-row, 0.20 inch centers, Polaris MK 84 Fire Control Type 2 Module hereinafter referred to as the Testplate wired with No. 18 AWG and No. 24 AWG wire and numerous individual wrapped connections wrapped with No. 18 AWG and No. 24 AWG wire were used during the evaluation. The Testplate was subjected to Visual Examination, Wrapper Resistance, Thermal Shock, Salt Spray, Vibration, and Current Overload Tests in accordance with Specification OS-11120. The individual wraposts were subjected to Visual Examination, Wrapper Resistance, Wrapper Stripping, Unwrapping, and Gas Tight Area Tests in accordance with Specification OS-11120. The wrapped connections, including those on the Testplate, consisted of wraposts containing the initial wrap, wraposts that had been rewrapped 10 times, and wraposts that had been rewrapped 25 times. Author