APPROXIMATION METHOD FOR FIRING WIRE-BRIDGE EED'S AT CONSTANT POWER,

reportActive / Technical Report | Accession Number: AD0650133 | Need Help?

Abstract:

Even though its bridge resistance may vary widely an electro-explosive device EED can be fired under nearly constant-power conditions using a special power supply. The supply should have a source impedance equal to the geometric mean of the EEDs expected minimum and maximum resistance during firing. Electro-thermal parameter measurements and equations can be used to compute the optimum source impedance. Per cent regulation and error figures can also be computed. Author