EFFECTS OF DIFFUSER LENGTH ON THE PERFORMANCE OF EJECTORS WITHOUT INDUCED FLOW

reportActive / Technical Report | Accession Number: AD0262888 | Open PDF

Abstract:

An investigation of ejectors without induced flow was made to determine the effects of varying diffuser lengths on ejector performance. Four 18-deg half angle conical nozzles having constant exit diameters and different throat diameters and two contoured nozzles having zero-deg half angles at the exit were used as the ejector driving nozzles. Unheated air was used for all tests. The diffuser length-to-diameter ratios were varied between 0.7 and 21.5, and three cylindrical ducts of different diameters were used both with and without a subsonic diffuser. An empirical method was developed to estimate the starting and operating pressure ratios of such ejector configurations using simple-determined one-dimensional normal shock relationships.

Security Markings

DOCUMENT & CONTEXTUAL SUMMARY

Distribution:
Approved For Public Release
Distribution Statement:
Approved For Public Release; Distribution Is Unlimited.

RECORD

Collection: TR
Identifying Numbers