Accession Number:

ADB806580

Title:

An Investigation of Aircraft Heaters. 11 - Measured and Predicted Performance of a Slotted-Fin Exhaust Gas and Air Heat Exchanger

Corporate Author:

CALIFORNIA UNIV LOS ANGELES

Report Date:

1943-04-01

Abstract:

Thermal and pressure drop performance data are given on slotted-fin heat exchanger. Measurements were made using up to 7000 lbhr of exhaust gas and up to 5000 lbhr ventilating air. Inlet exhaust gas temperature was maintained at 1400 deg F, and that of the ventilating air was 95 deg F. Three different cross-flow air shrouds were used in tests. Thermal output of heater was determined by enthalpy changes of ventilating air. Maximum measured rate of heat transfer was 216,000 BTU per hour.

Descriptive Note:

Wartime rept.

Pages:

0052

Identifiers:

Communities Of Interest:

Distribution Statement:

Approved for public release; distribution is unlimited.

File Size: