Accession Number:

ADA191870

Title:

Analysis Procedure for Muzzle Motion Data Collected with the Schmidt Displacement Transducer Instrumentation

Personal Author(s):

Corporate Author:

ARMY BALLISTIC RESEARCH LAB ABERDEEN PROVING GROUND MD

Report Date:

1987-11-01

Abstract:

In many gun accuracy investigations the projectile as well as the muzzle dynamics during shot exit must be determined. Not every instrumentation used for gun barrel motion measurements is suitable for the obtainment of the muzzle motion due to temporal resolution and spatial accuracy requirements. An instrumentation referred to as the Schmidt Displacement Transducer SDT has recently been developed at the Ballistic Research Laboratory which is well suited for these type of measurements. This report contains a brief review of instrumentation applicable to the measurement of barrel and muzzle motion, a description of the SDT instrumentation and its application for monitoring muzzle motion, an analysis procedure for SDT type of data for extracting the muzzle motion with respect to the ground, and the developed computer data analysis program with appropriate examples.

Descriptive Note:

Final technical rept.

Pages:

0128

Subject Categories:

Communities Of Interest:

Distribution Statement:

Approved for public release; distribution is unlimited.

File Size:

3.01MB