DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
ADA076334
Title:
Effects of Proof-Test on the Strength and Fatigue Life of a Unidirectional Composite.
Corporate Author:
DYNA EAST CORP WYNNEWOOD PA
Report Date:
1979-05-01
Abstract:
The effects of a static proof-load on the statistical distribution of the static strength and fatigue life of a unidirectional graphite-epoxy laminate As-3501-05 are investigated experimentally. Loading mode for both the static and fatigue tests is restricted to uniaxial tension in the fiber direction. 6-ply tension coupons with dimensions of 22.9 cm x 1.9 cm are used and all tests are conducted using a closed-loop Instron tester, under room temperature 21 C and ambient humidity 60 R.H. conditions. The data are analyzed using a two-parameter Weibull distribution in conjunction with the max. likelihood method for parameter estimation. Results show that proof-load can guarantee a min. static strength, and to less degree can assure a min. fatigue life. Author
Descriptive Note:
Interim technical rept. 1 Apr 78-31 Mar 79,
Supplementary Note:
DOI: 10.21236/ADA076334
Pages:
0032
Contract Number:
F33615-77-C-5039
File Size:
12.20MB