DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
ADA063751
Title:
Limiting Point-Source Detection Capabilities of Two-Dimensional, Scanned, Optical Detector Arrays in Constant False-Alarm Systems
Corporate Author:
MASSACHUSETTS INST OF TECH LEXINGTON LINCOLN LAB
Report Date:
1978-11-03
Abstract:
An optical point-source detection system in which a constant number of false alarms is allowed per data set exposure time based on the post- detection processing, is considered. The detector is a two-dimensional scanned array. With a single threshold determined solely by the allowed false alarms, that minimum average signal necessary to satisfy a given requirement on the probability of detection for various background sky, in this instance and electronic noise levels is determined. This development leads to a critical signal-noise expression at the first photon to charge-carrier conversion surface which is not an explicit function of the standard deviation of the signal. This expression is used to compare the detection performances of noise-free and of noisy detector arrays using the parameters of typical, ground-based, satellite surveillance systems.
Descriptive Note:
Technical note
Supplementary Note:
DOI: 10.21236/ADA063751
Pages:
0029
Distribution Statement:
Approved for public release; distribution is unlimited.
Contract Number:
F19628-78-C-0002
File Size: