DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
AD1084235
Title:
A High Resolution Passive Flux Meter Approach Based on Colorimetric Responses
Corporate Author:
University of Florida Gainesville United States
Report Date:
2019-03-01
Abstract:
The standard Passive Flux Meter PFM is a well-established device used for measuring groundwater and contaminant mass flux in screened wells. The PFM is a permeable device that contains granular activated carbon impregnated with alcohol tracers which is deployed in a flow field for a designated period of time and requires laboratory analysis to quantify Darcy flux. To expedite test results, a modified PFM based on the visual analysis of colorimetric responses, herein referred to as a colorimetric Passive Flux Meter cPFM, was developed. Various dyes and sorbents were evaluated for their ability to determine colorimetric response to water flow.
Descriptive Note:
Technical Report,30 Apr 2014,30 Apr 2018
Pages:
0076
Distribution Statement:
Approved For Public Release;
Contract Number:
14-C-0024
File Size:
3.00MB