Accession Number:

AD0920984

Title:

Gunfire Tests of F-15 no. 1 Fuel Tank Explosion Suppression Foam Configuration

Personal Author(s):

Corporate Author:

AERONAUTICAL SYSTEMS DIV WRIGHT-PATTERSON AFB OH

Report Date:

1974-04-01

Abstract:

Gunfire testing was conducted to determine whether a 50 voiding foam configuration for the F-15 No. 1 fuselage fuel tank can suppress fuel vapor explosions to maximum peak overpressures of less than the structural strength limitation of the tank. The resulting peak overpressures stayed well within the 15 psig limit as established by the F-15 Fuel System Design Analysis Report, MDC 0372.

Descriptive Note:

Final rept. 7 May-31 Aug 1973

Supplementary Note:

Prepared in cooperation with Air Force Flight Dynamics Lab., Wright-Patterson AFB, Ohio 45433. Original contains color plates: All DDC reproductions will be in black and white.

Pages:

0032

Communities Of Interest:

Distribution Statement:

Approved for public release; distribution is unlimited

File Size:

1.81MB