Accession Number:

AD0904603

Title:

(Hg,Cd)Te High Reliability.

Personal Author(s):

Corporate Author:

HONEYWELL RADIATION CENTER LEXINGTON MA

Report Date:

1972-06-30

Abstract:

This final report describes the design and responsive parameters of ten high reliability single element Hg,CdTe detector devices. The infrared sensors, designated by Honeywell Part Number DLK13G1 are optimized for detectivity in the 8 to 14-micron spectral region. The units, with exception of final pump bake temperature, were fabricated as standard high reliability product line devices. In addition to achieving high performance, the goal was to provide devices capable of high temperature storage and vacuum integrity. With no firm program objective, efforts were directed at meeting the temperature vs altitude operational requirements for class 1 equipment of MIL-STD-810B. The program has been successful. The detectors exhibited performance in excess of the minimum requirements. Sound process techniques were applied for conformance to MIL-STD-810B. Author

Descriptive Note:

Final technical rept. Oct 71-May 72,

Pages:

0048

Identifiers:

Subject Categories:

Communities Of Interest:

Contract Number:

DAAK02-72-C-0112

File Size:

0.00MB

Full text not available:

Request assistance