DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
AD0872299
Title:
The Compatibility of VARIOUS Metals with MHF-3
Corporate Author:
NAVAL WEAPONS CENTER CHINA LAKE CA
Report Date:
1970-07-01
Abstract:
The compatibility of various pure metals with MHF-3 was determined at 74C 165F. Metals investigated included titanium, copper, iron, aluminum, and nickel in the annealed and cold-worked conditions, and chemically deposited chromium. Tests were conducted in an all pyrex, torch-sealed pressure vessel. Pressure changes were recorded over a 94 day period. Post exposure evaluations of the metals were made by electron microscopic examination, microprobe analysis, and tensile tests.
Descriptive Note:
Technical publication
Supplementary Note:
GIDEP-347.15.00.00-X7-06
Pages:
0044
Distribution Statement:
Approved for public release; distribution is unlimited.
File Size:
2.45MB