Reliability Test of Valve, Check - Hydraulic Pressure Part No. 27-08560-1 Search for Critical Weakness.
Corporate Author:
GENERAL DYNAMICS/ASTRONAUTICS SAN DIEGO CA
Report Date:
1961-03-20
Abstract:
The purpose of this test was to determine the operational characteristics external leakage rates of the Valves, Check-Hydraulic Pressure, while being subjected to three 3 temperature-vibration levels, and the changes in test unit performance and body outside diameter as a result of these tests. Author