DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
AD0773596
Title:
The Use of Small, Pre-Cracked Bend Specimens for Quality Control Purposes.
Corporate Author:
CALIFORNIA UNIV LOS ANGELES SCHOOL OF ENGINEERING AND APPLIED SCIENCE
Report Date:
1973-11-01
Abstract:
The difficulties involved in using valid ASTM K sub Ic specimens for quality control purposes are described. It is shown from tests on steels and titanium alloys that values of K sub Ic can be obtained at lower cost from small specimens. If fracture initiation occurs before general yield, K sub Ic can be determined from the load required to cause crack extension. If fracture occurs after general yield, K sub Ic can be determined from the critical plane strain crack tip opening displacement or from the notch root contraction. The effect of a steeply rising plane strain R-curve can be corrected by using a newly developed R-extrapolation technique. Simplified versions of the methods involved are described whereby small specimens can be used to determine whether a material satisfies specifications for quality control. These simplified versions require little or no calculation for quality control-testing once master nomographs have been drawn up. Author
Descriptive Note:
Technical rept.,
Pages:
0048
Contract Number:
DAHC04-69-C-0008
File Size:
0.00MB