Accession Number:

AD0745581

Title:

Personnel Protection from Cold in a 7 Man Life Raft

Corporate Author:

AIR FORCE AEROSPACE MEDICAL RESEARCH LAB WRIGHT-PATTERSON AFB OH

Report Date:

1972-05-01

Abstract:

A physical test was conducted to determine the protective properties of a 7 man life raft in the cold. From the known energy output of 2 heaters and 34 measured temperatures, the insulation values for the total raft, its floor, ceiling, sidewalls, back and front could be derived. The raft was floating in a swimming pool and water temperature maintained at 21.50. Two graphs show the increasing cold protection when 1 to 7 subjects occupy the raft.

Descriptive Note:

Technical rept.

Pages:

0013

Communities Of Interest:

Modernization Areas:

Distribution Statement:

Approved for public release; distribution is unlimited.

File Size:

0.48MB