Accession Number:

AD0641559

Title:

EVALUATION OF THE RESPONSE OF SILICON DIODE DOSIMETERS TO FAST NEUTRONS,

Corporate Author:

ARMY NUCLEAR DEFENSE LAB EDGEWOOD ARSENAL MD

Report Date:

1966-10-01

Abstract:

Conductivity-modulated, silicon p-n junctions of two base widths 10- and 50-mil were exposed to a burst of fast neutrons. High-level lifetime, reverse-recovery lifetime, and forward voltage at four constant current levels were correlated with fast neutron kerma as measured by threshold detectors. This correlation showed that the sensitivity of the diodes varied with respect to kerma. The curves of high-level lifetime versus kerma and reverse-recovery lifetime versus kerma have two changes in slope, at 100000 ergsg and at 1000000 ergsg. The 10-mil diodes exhibited excellent reproducibility for both lifetime measurements however, only 55 percent of the forward-voltage measurements were within plus or minus 10 percent of the average. The lifetime measurements of the 50-mil diodes were very poor only 31 percent of the data was within plus or minus 10 percent while the forward-voltage measurements were better 84 percent of the data was within plus or minus 10 percent. Author

Pages:

0040

Subject Categories:

File Size:

0.00MB

Full text not available:

Request assistance