DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
AD0612934
Title:
NEW HIGH TEMPERATURE INFRARED TRANSMITTING GLASSES.
Corporate Author:
TEXAS INSTRUMENTS INC DALLAS
Report Date:
1962-10-09
Abstract:
The chalcogenide glass system studied this quarter was formed from silicon Group IV element, antimony Group V element, and selenium the chalcogen. The system was studied in essentially the same manner as the silicon-antimony-sulfur system reported in the first quarterly report. The results obtained from 42 samples of different composition are given. All sample numbers of compositions that formed glasses are marked with an asterisk. The measured and corrected softening points of each glass are given and range from a maximum of 490 C down to a minimum value of 163 C for a 85 selenium glass. The softening points were measured using the apparatus described. Author
Descriptive Note:
Quarterly technical rept. no 2, 1 Aug-30 Sep 62.
Supplementary Note:
See also AD-440 439.
Pages:
0008
Contract Number:
Nonr381000
File Size:
0.00MB