DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
AD0601713
Title:
STUDY AND INVESTIGATION OF MILLIMETER AND SUBMILLIMETER WAVE RECEIVER TECHNIQUES.
Corporate Author:
ILLINOIS UNIV URBANA ELECTRICAL ENGINEERING RESEARCH LAB
Report Date:
1964-05-01
Abstract:
The program has as its goal the development of video detection techniques which are appropriate for the millimeter and submillimeter range of the spectrum. Measurement of the sensitivity of the TGS pyroelectric effect detector indicates a minimum detectable signal level of approximately 4 microwatts. Additional studies on the theory of the reflecting beam waveguide indicate that at least two reflector shapes are permitted by the approximate theory developed for the analysis. If any differences in the electromagnetic fields corresponding to these two types of reflectors exist, they are obscured by the approximations made in the analysis. Author
Pages:
0015
Contract Number:
AF 30(602)-3046
File Size:
0.00MB