Accession Number:

AD0488355

Title:

FIELD CHECK OF TACTICAL DOSIMETERS IM-185(XE), INDIVIDUAL DOSIMETERS DT- 236(XE), AND OTHER DOSIMETRY SYSTEMS.

Corporate Author:

ARMY ELECTRONICS COMMAND FORT MONMOUTHNJ

Report Date:

1966-09-09

Abstract:

The primary objective of Project 2.4 participation in the KIWI-TNT Transient Nuclear Test was to test the performance of laboratory models of SEMIRAD-type mixed radiation dosimeters IM-185XE and experimental models of the individual dosimeters DT-236XE. The secondary objective was to expose different types of dosimetry to establish the neutron and gamma doses at the distances at which the measurements took place. Different types of passive dosimeters and the experimental models were enclosed in containers, and each group was placed along a straight line on ground at 11 distances ranging from 23 to 400 meters. The data analysis shows that the results obtained from the passive dosimeters agree much better for one and the same system than among different systems.

Descriptive Note:

Project officers rept.,

Supplementary Note:

Report on Operation Rover, KIWI-TNT Experiment. KIWI-TNT Project 2.4

Pages:

0044

Identifiers:

Subject Categories:

Communities Of Interest:

Modernization Areas:

Distribution Statement:

Approved for public release; distribution unlimited