Accession Number:

AD0460363

Title:

SAFETY HAZARD CLASSIFICATION OF WATER-WET EXPLOSIVES

Personal Author(s):

Corporate Author:

PICATINNY ARSENAL DOVER NJ AMMUNITION DEVELOPMENT AND ENGINEERING DIRECTORATE

Report Date:

1965-02-01

Abstract:

Eithteen water-wet explosives were studied to determine whether they could support detonations. Of the 18 explosives tested, 15 sustained detonations when saturated with water. All explosives tested were found to sustain detonations at water levels that could be encountered in manufacturing operations following the filtering operation. Therefore, the filtered explosives should be assigned a safety hazard classification of Class 9.

Descriptive Note:

Technical rept.

Supplementary Note:

DOI: 10.21236/AD0460363

Pages:

0033

Subject Categories:

Communities Of Interest:

Modernization Areas:

Distribution Statement:

Approved for public release; distribution is unlimited. Document partially illegible.