DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
AD0271143
Title:
DETERMINATION OF DEFECT GEOMETRY BY ULTRASONIC PULSE ANALYSIS TESTING
Corporate Author:
WATERTOWN ARSENAL LABS MASS
Report Date:
1962-01-01
Abstract:
Test specimens containing artificial defects of various configurations were consecutively subjected to a conventional ultrasonic pulse echo test and a novel pulse reflection method employing polychromatic ultrasonic energy. Results are compared from the viewpoint of the effectiveness of these two methods to differentiate among various flaw geometries. It was found that the polychromatic pulse method permits a more conclusive geometry inspection for defects which are smaller than the ultrasonic search beam diameter. Author
Pages:
0001
File Size:
0.00MB