DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
AD0260858
Title:
RESEARCH AND DEVELOPMENT OF SUPERPOWER THYRATRONS
Corporate Author:
GENERAL ELECTRIC CO SCHENECTADY N Y
Report Date:
1961-05-24
Abstract:
Efforts were continued on the development of thyratron tubes capable of switching a peak power of 50 megawatts at an average power of 200 kilowatts. Full objective ratings have not been achieved when using a saturable reactor in the anode lead, when using an anode design intended to distribute anode dissipation, or when utilizing a charging circuit having charging triodes. This suggests that anode dissipation AND RECOVERY TIME ARE NOT THE SOLE FACTORS WHICH LIMIT THE Z-5212 to subobjective power levels. Test data are presented on Z-5212, Nos. 9A, 11A, and 13. The highest performing tube, No. 11A, is capable of operating steadily at 35 KV, and seven amperes average. Distortion of the gradient grid is discussed. Author
Pages:
0001
Contract Number:
DA36 039SC74850
File Size:
0.00MB