DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
AD0260802
Title:
REACTIVE ERROR IN THE MEASUREMENT OF RECTAL TEMPERATURE IN THE COLD
Corporate Author:
ARCTIC AEROMEDICAL LAB FORT WAINWRIGHT ALASKA
Report Date:
1961-03-01
Abstract:
The reliability of rectal temperatures measured in the cold, using clinical mercury thermometers at various temperatures prior to insertion, has been assessed. It has been shown that the reactive error in measurement may be as great as 1.0 C the more usual value is approximately 0.3 C. A new term, interactive error, has been defined, as a means of convenient reference to error caused by a general change in the condition of an animal at the time of measurement. The implications of these two types of error to physiological measurements in general has been discussed. Author
Pages:
0001
File Size:
0.00MB